UNSW Test Turbine Vibration and Pressure Measurements Measurements contain vibration and pressure readings on a simplified turbine test rig. Measurements were taken at a constant speed of 2000 rpm. The test rig consists of a 19 blade arrangement. Measurements are provided for all 19 blades of nominally the same dimension. An additional measurement is also provided for one blade being of a smaller dimension to simulate a blade fault. Further information of the test setup can be found at he corresponding publication link below. 'http://data-acoustics.com/wp-content/uploads/2013/08/Turbine_meta_data.xml' http://dx.doi.org/10.1016/j.ymssp.2012.11.006 Gareth Forbes Gareth.Forbes@curtin.edu.au 02/07/10 This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 Australia License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/au/ or send a letter to Creative Commons, 444 Castro Street, Suite 900, Mountain View, California, 94041, USA http://data-acoustics.com/?p=183 Good condition and with fault (see description above for details) Australia New South Wales Kensington Barker street Nominal 5 kW 2000 rpm 19 flat blade arrangement 20x50x1.2mm and 20x50x0.8mm(simulated fault) 65336 Hz 10 seconds 1 Turbine casing pressure tapping 1/4 inch microphone 2 Turbine casing Accelerometer 3 Input shaft Proximity probe (once per rev tachometer signal)